4820-01-186-5531 VALVE,CHECK Index 5915-01-186-5533 FILTER,BAND PASS

National Stock Number:
5915-01-186-5532

Federal Supply Class:
5915

National Item Identification Number:
011865532

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
77C717561P00103538LOCKHEED MARTIN CORPORATION
F-1057608715CEN ELECTRONICS A DIV OF CHLORIDE POWER ELECTRONICS INC


Techincal Specification:
REFERENCE FREQUENCY PER FUNCTION5.12 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
5.12 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS10.75 1ST BAND PASS 1ST FUNCTION
10.75 2ND BAND PASS 2ND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
FREQUENCY BAND WIDTH PER FUNCTION5.035 KILOHERTZ 1ST BAND PASS AND
5.205 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
5.035 KILOHERTZ 2ND BAND PASS AND
5.205 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 WIRE HOOK INPUT 1ST FUNCTION
2 WIRE HOOK OUTPUT 2ND FUNCTION
4 WIRE HOOK GROUND 3RD FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
INPUT IMPEDANCE PER FUNCTION W/LOAD2.0 KILOHMS 1ST BAND PASS 1ST FUNCTION
2.0 KILOHMS 2ND BAND PASS 2ND FUNCTION
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT2.0 KILOHMS 1ST BAND PASS 1ST FUNCTION
2.0 KILOHMS 2ND BAND PASS 2ND FUNCTION
OVERALL HEIGHT5.200 INCHES NOMINAL
BODY LENGTH4.375 INCHES NOMINAL
BODY HEIGHT4.500 INCHES NOMINAL
BODY WIDTH2.750 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH3.500 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.000 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.250 INCHES
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION4.675 KILOHERTZ 1ST BAND PASS AND
5.035 KILOHERTZ 1ST BAND PASS AND
5.205 KILOHERTZ 1ST BAND PASS AND
5.565 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
4.675 KILOHERTZ 2ND BAND PASS AND
5.035 KILOHERTZ 2ND BAND PASS AND
5.205 KILOHERTZ 2ND BAND PASS AND
5.565 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM 1ST BAND PASS AND
1.2 MAXIMUM 1ST BAND PASS 1ST FUNCTION
60.0 MINIMUM 2ND BAND PASS AND
1.2 MAXIMUM 2ND BAND PASS 2ND FUNCTION
OPERATING TEMP RANGE15.0 TO 45.0 DEG CELSIUS
SPECIAL FEATURESUNPACKAGED UNIT WEIGHT: OZ24.000