4820-01-226-2005 VALVE,SAFETY RELIEF Index 5915-01-226-2008 FILTER,BAND PASS

National Stock Number:
5915-01-226-2006

Federal Supply Class:
5915

National Item Identification Number:
012262006

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
SF394-100-4AA56216TELEDYNE WIRELESS, LLC


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION300.0 WATTS BLANK ALL FUNCTIONS
BODY LENGTH3.780 INCHES NOMINAL
BODY MATERIALMETAL
BODY OUTSIDE DIAMETER0.500 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS33.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK AND 50.0 MINIMUM BLANK ALL FUNCTIONS
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION344.00 MEGAHERTZ BLANK AND 444.00 MEGAHERTZ BLANK ALL FUNCTIONS
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
INPUT TERMINAL MANUFACTURER CODE33174
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0.65 BLANK ALL FUNCTIONS
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK ALL FUNCTIONS
OVERALL LENGTH5.380 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL ALL FUNCTIONS
OUTPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
OUTPUT TERMINAL MANUFACTURER CODE33174
REFERENCE FREQUENCY PER FUNCTION394.0 MEGAHERTZ BLANK ALL FUNCTIONS
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK ALL FUNCTIONS
SPECIAL FEATURESUNPACKAGED UNIT WEIGHT: OZ40.350
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION194.00 MEGAHERTZ BLANK AND 344.00 MEGAHERTZ BLANK AND 444.00 MEGAHERTZ BLANK AND 594.00 MEGAHERTZ BLANK ALL FUNCTIONS
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION344.0 MEGAHERTZ BLANK AND 444.0 MEGAHERTZ BLANK ALL FUNCTIONS
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK ALL FUNCTIONS


Click here to Register for Free 30-day Trial