OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| 3.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| 3.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
| 3.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
| 3.0 5TH RADIO INTERFERENCE 5TH FUNCTION |
INCLOSURE TYPE | ENCASED |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 5 SCREW INPUT 1ST FUNCTION |
| 5 SCREW OUTPUT 2ND FUNCTION |
MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
| 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
| 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| 115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| 115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
| 115.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION |
| 115.0 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| 60.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| 60.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
| 60.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
| 60.0 5TH RADIO INTERFERENCE 5TH FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| 1.15 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| 1.15 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
| 1.15 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION |
| 1.15 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION |
OVERALL HEIGHT | 4.000 INCHES NOMINAL |
BODY LENGTH | 5.120 INCHES NOMINAL |
BODY HEIGHT | 3.500 INCHES NOMINAL |
BODY WIDTH | 2.000 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.125 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 2.500 INCHES NOMINAL |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
NOMINAL THREAD SIZE | 0.138 INCHES |
SPECIAL FEATURES | FIVE FILTERED FUNCTIONS |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
| INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
| INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
| INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
| INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION |
MAXIMUM TEMP RISE | 25.0 DEG CELSIUS |
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 230.0 VOLTS AT SEA LEVEL |
VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 500.0 |
OPERATING TEMP RANGE | -55.0 TO 85.0 DEG CELSIUS |
BODY MATERIAL | METAL |