5915-01-254-2122 FILTER,BAND PASS Index 5915-01-254-2124 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-254-2123

Federal Supply Class:
5915

National Item Identification Number:
012542123

Description:
FILTER,BAND SUPPRESSION

Detail:
AN ITEM DESIGNED TO SUPPRESS FREQUENCIES WITHIN A SPECIFIED RANGE (BAND) AND TO PASS FREQUENCIES OUTSIDE THE RANGE (BAND). EXCLUDES A SINGLE INDUCTANCE, A SINGLE CAPACITANCE, OR A SINGLE RESISTANCE. SEE COIL (AS MODIFIED); CAPACITOR (AS MODIFIED); AND RESISTOR (AS MODIFIED).


Manufacturer Information:
90370060656INTEGRATED MICROWAVE CORPORATION


Techincal Specification:
BODY HEIGHT1.000 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH2.900 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MAXIMUM BLANK AND 30.0 MINIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.200 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH4.800 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION1.1735 GIGAHERTZ BLANK AND 1.1765 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
INPUT TERMINAL MANUFACTURER CODE60656
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-30.0 TO 130.0 CELSIUS
OUTPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
OUTPUT TERMINAL MANUFACTURER CODE60656
OVERALL LENGTH5.000 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
NOMINAL THREAD SIZE0.112 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION1.175 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.17 GIGAHERTZ BLANK AND 1.1735 GIGAHERTZ BLANK AND 1.1765 GIGAHERTZ BLANK AND 1.18 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES


Click here to Register for Free 30-day Trial