4820-01-259-5503 VALVE,BALL Index 5930-01-259-5505 SWITCH,PRESSURE

National Stock Number:
5915-01-259-5504

Federal Supply Class:
5915

National Item Identification Number:
012595504

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
ST437F16N61SN18355THE BOEING COMPANY


Techincal Specification:
BODY LENGTH0.698 INCHES NOMINAL
BODY MATERIALMETAL
BODY OUTSIDE DIAMETER0.080 INCHES NOMINAL
BODY SURFACE TREATMENTGOLD
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY61 FRICTION W/GROUNDING STRAP AND PIN OUTPUT 2ND FUNCTION
INCLOSURE TYPEENCASED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
OVERALL LENGTH0.808 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE600.0 VOLTS AT SEA LEVEL
MOUNTING FACILITY TYPE AND QUANTITY1 TERMINAL
OPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 4TH RADIO INTERFERENCE 4TH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 5TH RADIO INTERFERENCE 5TH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 6TH RADIO INTERFERENCE 6TH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION120.0 VOLTS AC 1ST RADIO INTERFERENCE AND 200.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION120.0 VOLTS AC 2ND RADIO INTERFERENCE AND 200.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION120.0 VOLTS AC 3RD RADIO INTERFERENCE AND 200.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION120.0 VOLTS AC 6TH RADIO INTERFERENCE AND 200.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION120.0 VOLTS AC 4TH RADIO INTERFERENCE AND 200.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION120.0 VOLTS AC 5TH RADIO INTERFERENCE AND 200.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION
SPECIAL FEATURES61 FILTERED CONTACTS
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 1ST RADIO INTERFERENCE 1ST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 2ND RADIO INTERFERENCE 2ND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 3RD RADIO INTERFERENCE 3RD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 4TH RADIO INTERFERENCE 4TH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 5TH RADIO INTERFERENCE 5TH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 6TH RADIO INTERFERENCE 6TH FUNCTION
PRECIOUS MATERIAL AND LOCATIONCONTACT SURFACES GOLD
PRECIOUS MATERIALGOLD
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACE
VIBRATION RESISTANCE RANGE IN HERTZ+5.0 TO 2000.0


Click here to Register for Free 30-day Trial