FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
10907-413619EMS DEVELOPMENT CORPORATION
2141-0400LSP2SPECTRUM CONTROL, INC.
7117828-406481NORTHROP GRUMMAN SYSTEMS CORPORATION
7117828-417863LITTON SYSTEMS INC GUIDANCE AND CONTROL SYSTEMS DIV
E-182523160LINDGREN RF ENCLOSURES INC ELMAG DIV
2141-04033095SPECTRUM CONTROL INC
RF10907-413619EMS DEVELOPMENT CORPORATION
M168659901MTK ELECTRONICS INC


Techincal Specification:
BODY HEIGHT1.870 INCHES NOMINAL
BODY LENGTH1.535 INCHES NOMINAL
BODY MATERIALMETAL
BODY SURFACE TREATMENTTIN
BODY WIDTH1.870 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY7 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG GROUND 3RD FUNCTION
INCLOSURE TYPEENCASED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
OVERALL HEIGHT2.220 INCHES NOMINAL
OVERALL LENGTH2.230 INCHES NOMINAL
MAXIMUM TEMP RISE25.0 CELSIUS
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.112 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.5 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.5 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.5 4TH RADIO INTERFERENCE 4TH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.5 5TH RADIO INTERFERENCE 5TH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.5 6TH RADIO INTERFERENCE 6TH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.5 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 6TH RADIO INTERFERENCE 6TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE 3RD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 4TH RADIO INTERFERENCE 4TH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 5TH RADIO INTERFERENCE 5TH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 6TH RADIO INTERFERENCE 6TH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES
SPECIAL FEATURESSEVEN FILTERED FUNCTIONS