5915-01-273-0742 FILTER,BAND PASS Index 5915-01-273-0744 FILTER,BAND PASS

National Stock Number:
5915-01-273-0743

Federal Supply Class:
5915

National Item Identification Number:
012730743

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
5616440-2453711NAVAL SEA SYSTEMS COMMAND
8IB40-680/X10-0/050140K&L MICROWAVE LLC


Techincal Specification:
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS30.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK 1ST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.380 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.380 INCHES NOMINAL
AVERAGE LIFE RATING IN HOURS500000.0
BODY HEIGHT0.400 INCHES NOMINAL
BODY LENGTH1.500 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH0.500 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION669.50 MEGAHERTZ BLANK AND 690.50 MEGAHERTZ BLANK
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
INPUT TERMINAL MANUFACTURER CODE50140
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS8.0 BLANK
NOMINAL THREAD SIZE0.060 INCHES
OPERATING TEMP RANGE-20.0 TO 85.0 DEG CELSIUS
OUTPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
OUTPUT TERMINAL MANUFACTURER CODE50140
OVERALL LENGTH2.260 INCHES NOMINAL
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK
REFERENCE FREQUENCY PER FUNCTION680.0 MEGAHERTZ BLANK
VIBRATION RESISTANCE RANGE IN HERTZ+5.0 TO 2000.0
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.25 BLANK
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION669.5 MEGAHERTZ BLANK AND 690.5 MEGAHERTZ BLANK
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION662.00 MEGAHERTZ BLANK AND 669.50 MEGAHERTZ BLANK AND 690.50 MEGAHERTZ BLANK AND 700.00 MEGAHERTZ BLANK
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES