5915-01-295-4513 FILTER,BAND PASS Index 5915-01-295-4515 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-295-4514

Federal Supply Class:
5915

National Item Identification Number:
012954514

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
5616441-253711NAVAL SEA SYSTEMS COMMAND
DM6851-60/9.5-PX/PX50140K&L MICROWAVE LLC


Techincal Specification:
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK 1ST FUNCTION
BODY HEIGHT0.730 INCHES MINIMUM AND 0.770 INCHES MAXIMUM
BODY LENGTH0.980 INCHES MINIMUM AND 1.020 INCHES MAXIMUM
BODY WIDTH0.480 INCHES MINIMUM AND 0.520 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT 2ND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY4 PIN GROUND 3RD FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION55.25 MEGAHERTZ BLANK AND 64.75 MEGAHERTZ BLANK
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK
OVERALL HEIGHT0.960 INCHES MINIMUM AND 1.040 INCHES MAXIMUM
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED STUD
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
PRECIOUS MATERIAL AND LOCATIONBODY SURFACE GOLD
PRECIOUS MATERIALGOLD
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK
REFERENCE FREQUENCY PER FUNCTION60.0 MEGAHERTZ BLANK
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.3 BLANK
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION55.25 MEGAHERTZ BLANK AND 64.75 MEGAHERTZ BLANK
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION30.00 MEGAHERTZ BLANK AND 55.25 MEGAHERTZ BLANK AND 64.75 MEGAHERTZ BLANK AND 90.00 MEGAHERTZ BLANK
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE


Click here to Register for Free 30-day Trial