5365-01-309-8642 SPACER,SLEEVE Index 5930-01-309-8644 SWITCH,PRESSURE

National Stock Number:
5915-01-309-8643

Federal Supply Class:
5915

National Item Identification Number:
013098643

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
TPV0616B26MPN71468ITT CANNON LLC
TPV0B16B26MPN71468ITT CANNON LLC


Techincal Specification:
OPERATING CURRENT RATING PER FUNCTION IN AMPS15.0 1ST RADIO INTERFERENCE 1ST FUNCTION
15.0 2ND RADIO INTERFERENCE 2ND FUNCTION
15.0 3RD RADIO INTERFERENCE 3RD FUNCTION
15.0 4TH RADIO INTERFERENCE 4TH FUNCTION
15.0 5TH RADIO INTERFERENCE 5TH FUNCTION
15.0 6TH RADIO INTERFERENCE 6TH FUNCTION
INCLOSURE TYPEENCASED
FUNCTIONAL TERMINAL TYPE AND QUANTITY5 FRICTION W/GROUNDING STRAP AND PIN INPUT-OUTPUT
MOUNTING FACILITY TYPE AND QUANTITY27 TERMINAL
STYLE DESIGNATORFILTER CONNECTOR
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION120.0 VOLTS AC 1ST RADIO INTERFERENCE AND
200.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
120.0 VOLTS AC 2ND RADIO INTERFERENCE AND
200.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
120.0 VOLTS AC 3RD RADIO INTERFERENCE AND
200.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
120.0 VOLTS AC 4TH RADIO INTERFERENCE AND
200.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
120.0 VOLTS AC 5TH RADIO INTERFERENCE AND
200.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION
120.0 VOLTS AC 6TH RADIO INTERFERENCE AND
200.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
400.0 3RD RADIO INTERFERENCE 3RD FUNCTION
400.0 4TH RADIO INTERFERENCE 4TH FUNCTION
400.0 5TH RADIO INTERFERENCE 5TH FUNCTION
400.0 6TH RADIO INTERFERENCE 6TH FUNCTION
OVERALL LENGTH31.24 MILLIMETERS MAXIMUM
SPECIAL FEATURESTWENTY SIX FILTERED FUNCTIONS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION
INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION
INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION
MAXIMUM TEMP RISE25.0 DEG CELSIUS
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE500.0 VOLTS AT SEA LEVEL
OPERATING TEMP RANGE-55.0 TO 125.0 DEG CELSIUS
BODY MATERIALMETAL