5935-01-312-9125 CONNECTOR,RECEPTACLE,ELECTRICAL Index 5915-01-312-9127 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-312-9126

Federal Supply Class:
5915

National Item Identification Number:
013129126

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
08P228093-0398738HERLEY CHICAGO DBA STEWART WARNER ELECTRONICS
2850-AY55-B55097SHILOH INDUSTRIES INC
526-8499-0102X491ROCKWELL COLLINS INC. DBA ROCKWELL COLLINS FILTER PRODUCTS DIV FILTER PRODUCTS
526-8499-01095105ROCKWELL COLLINS, INC.


Techincal Specification:
REFERENCE FREQUENCY PER FUNCTION500.0 KILOHERTZ BLANK
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS8.0 BLANK
INCLOSURE TYPEHERMETICALLY SEALED
FREQUENCY BAND WIDTH PER FUNCTION496.50 KILOHERTZ BLANK AND
503.50 KILOHERTZ BLANK
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG INPUT 1ST FUNCTION
2 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
1 TAB, SOLDER LUG GROUND 3RD FUNCTION
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
OVERALL HEIGHT2.624 INCHES MAXIMUM
OVERALL WIDTH0.660 INCHES MINIMUM AND
0.680 INCHES MAXIMUM
BODY HEIGHT1.604 INCHES MINIMUM AND
1.696 INCHES MAXIMUM
BODY OUTSIDE DIAMETER0.432 INCHES MINIMUM AND
0.442 INCHES MAXIMUM
DISTANCE BETWEEN MOUNTING SURFACE AND LOWER END0.584 INCHES MINIMUM AND
0.616 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER0.123 INCHES MINIMUM AND
0.133 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH0.745 INCHES MINIMUM AND
0.755 INCHES MAXIMUM
FEATURES PROVIDEDSHOCK RESISTANT
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION490.50 KILOHERTZ BLANK AND
496.50 KILOHERTZ BLANK AND
503.50 KILOHERTZ BLANK AND
509.50 KILOHERTZ BLANK
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MAXIMUM BLANK AND
3.0 MINIMUM BLANK 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK
OPERATING TEMP RANGE-30.0 TO 85.0 DEG CELSIUS
BODY MATERIALMETAL
BODY SURFACE TREATMENTTIN


Click here to Register for Free 30-day Trial