4820-01-329-7861 VALVE,GLOBE Index 5930-01-329-7863 SWITCH,ROTARY

National Stock Number:
5915-01-329-7862

Federal Supply Class:
5915

National Item Identification Number:
013297862

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
10073-731414304L3HARRIS TECHNOLOGIES, INC.
2163752748ALPHA COMPONENTS INC


Techincal Specification:
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS2.0 MINIMUM 1ST BAND PASS 1ST FUNCTION AND 60.0 MAXIMUM 1ST BAND PASS 1ST FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS2.0 MINIMUM 2ND BAND PASS 2ND FUNCTION AND 60.0 MAXIMUM 2ND BAND PASS 2ND FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.594 INCHES MINIMUM AND 1.599 INCHES MAXIMUM
BODY HEIGHT2.195 INCHES MINIMUM AND 2.200 INCHES MAXIMUM
BODY LENGTH3.235 INCHES MINIMUM AND 3.240 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH0.995 INCHES MINIMUM AND 1.000 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN OUTPUT 2ND FUNCTION
FEATURES PROVIDEDSHOCK RESISTANT
FREQUENCY BAND WIDTH PER FUNCTION453.70 KILOHERTZ 2ND BAND PASS AND 456.30 KILOHERTZ 2ND BAND PASS
FREQUENCY BAND WIDTH PER FUNCTION453.70 KILOHERTZ 1ST BAND PASS AND 456.30 KILOHERTZ 1ST BAND PASS
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS11.5 1ST BAND PASS
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS11.5 2ND BAND PASS
LOAD IMPEDANCE PER FUNCTION5.1 KILOHMS 1ST BAND PASS
LOAD IMPEDANCE PER FUNCTION5.1 KILOHMS 2ND BAND PASS
INCLOSURE TYPEHERMETICALLY SEALED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONCRYSTAL 1ST BAND PASS 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONCRYSTAL 2ND BAND PASS 2ND FUNCTION
PROPRIETARY CHARACTERISTICSPACS
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED STUD
NOMINAL THREAD SIZE0.112 INCHES
OPERATING TEMP RANGE+0.0/+60.0 DEG CELSIUS
OVERALL HEIGHT2.470 INCHES MINIMUM AND 2.505 INCHES MAXIMUM
REFERENCE FREQUENCY PER FUNCTION455.0 SINGLE RADIO INTERFERENCE PULSES PER SECOND
REFERENCE FREQUENCY PER FUNCTION455.0 SINGLE RADIO INTERFERENCE TWO PHASE TO TWO PHASE
SOURCE IMPEDANCE RATING PER FUNCTION5.1 KILOHMS 1ST BAND PASS
SOURCE IMPEDANCE RATING PER FUNCTION5.1 KILOHMS 2ND BAND PASS
SPECIAL FEATURESTWO FILTERED FUNCTIONS
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION450.60 KILOHERTZ 2ND BAND PASS 2ND FUNCTION AND 453.70 KILOHERTZ 2ND BAND PASS 2ND FUNCTION AND 456.30 KILOHERTZ 2ND BAND PASS 2ND FUNCTION AND 459.40 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION450.60 KILOHERTZ 1ST BAND PASS 1ST FUNCTION AND 453.70 KILOHERTZ 1ST BAND PASS 1ST FUNCTION AND 456.30 KILOHERTZ 1ST BAND PASS 1ST FUNCTION AND 459.40 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
VIBRATION RESISTANCE RANGE IN HERTZ+10.0/+2000.0
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE


Click here to Register for Free 30-day Trial