5915-01-332-0676 FILTER,BAND PASS Index 5930-01-332-0678 SWITCH,ROTARY

National Stock Number:
5915-01-332-0677

Federal Supply Class:
5915

National Item Identification Number:
013320677

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
3FS416555815TEXAS SPECTRUM ELECTRONICS INC
803551-596214RAYTHEON COMPANY
A-576623939THE CAPTOR CORPORATION


Techincal Specification:
BODY HEIGHT1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM
BODY LENGTH3.240 INCHES MINIMUM AND 3.260 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH2.620 INCHES MINIMUM AND 2.640 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.180 INCHES MINIMUM AND 1.200 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.800 INCHES MINIMUM AND 2.820 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG GROUND 3RD FUNCTION
FEATURES PROVIDEDMOISTURE RESISTANT AND SHOCK RESISTANT
FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ0.0 AND 0.1 AND 1.0 AND 10.0 AND 100.0 AND 1000.0
FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS10.0 AND 22.5 AND 42.5 AND 45.0 AND 70.0
INCLOSURE TYPEHERMETICALLY SEALED
INPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
INPUT TERMINAL MANUFACTURER CODE96214
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
OVERALL LENGTH4.238 INCHES MINIMUM AND 4.300 INCHES MAXIMUM
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE56.0 VOLTS AT SEA LEVEL
MAXIMUM VOLTAGE DROP PER FUNCTION2.8 VOLTS DC BLANK
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.138 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 BLANK
OPERATING TEMP RANGE-55.0 TO 75.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION28.0 VOLTS DC BLANK
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
SPECIAL FEATURESONE FILTERED FUNCTION; TWO UNFILTERED FUNCTIONS
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 500.0


Click here to Register for Free 30-day Trial