5915-01-332-4488 FILTER,BAND PASS Index 5915-01-332-4490 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-332-4489

Federal Supply Class:
5915

National Item Identification Number:
013324489

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
1425AS92302387NAVAL AIR WARFARE CENTER AIRCRAFT DIV
1425AS92330003NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER
F-763112598RLC ELECTRONICS, INC
X5C25-137/X4-N/CTP MODIFIED50140K&L MICROWAVE LLC


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION50.0 WATTS BLANK
BODY HEIGHT2.000 INCHES MAXIMUM
BODY LENGTH10.800 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH6.500 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS1.0 MINIMUM BLANK AND 50.0 MAXIMUM BLANK
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH6.000 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH5.400 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION
FEATURES PROVIDEDSHOCK RESISTANT
FREQUENCY BAND WIDTH PER FUNCTION135.00 MEGAHERTZ BLANK AND 139.00 MEGAHERTZ BLANK
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
INPUT TERMINAL MANUFACTURER CODE50140
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 BLANK
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
OVERALL LENGTH12.000 INCHES MINIMUM AND 12.400 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY6 SLOT
MOUNTING SLOT WIDTH0.180 INCHES NOMINAL
OPERATING TEMP RANGE-28.0 TO 65.0 CELSIUS
OUTPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
OUTPUT TERMINAL MANUFACTURER CODE50140
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK
REFERENCE FREQUENCY PER FUNCTION137.0 MEGAHERTZ BLANK
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION126.00 MEGAHERTZ BLANK AND 135.00 MEGAHERTZ BLANK AND 139.00 MEGAHERTZ BLANK AND 148.00 MEGAHERTZ BLANK
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION135.0 MEGAHERTZ BLANK AND 139.0 MEGAHERTZ BLANK
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 33.0


Click here to Register for Free 30-day Trial