5915-01-334-4790 FILTER,BAND PASS Index 5915-01-334-4792 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-334-4791

Federal Supply Class:
5915

National Item Identification Number:
013344791

Description:
FILTER,BAND SUPPRESSION

Detail:
AN ITEM DESIGNED TO SUPPRESS FREQUENCIES WITHIN A SPECIFIED RANGE (BAND) AND TO PASS FREQUENCIES OUTSIDE THE RANGE (BAND). EXCLUDES A SINGLE INDUCTANCE, A SINGLE CAPACITANCE, OR A SINGLE RESISTANCE. SEE COIL (AS MODIFIED); CAPACITOR (AS MODIFIED); AND RESISTOR (AS MODIFIED).


Manufacturer Information:
1185AS156-130003NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER
40100450545HENDERSON H F INDUSTRIES


Techincal Specification:
BODY HEIGHT3.500 INCHES NOMINAL
BODY LENGTH8.000 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH6.000 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM 1ST BAND SUPPRESSION AND 60.0 MAXIMUM 1ST BAND SUPPRESSION 1ST FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM 3RD BAND SUPPRESSION AND 60.0 MAXIMUM 3RD BAND SUPPRESSION 3RD FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM 2ND BAND SUPPRESSION AND 60.0 MAXIMUM 2ND BAND SUPPRESSION 2ND FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH5.500 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH6.500 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 SCREW INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 SCREW OUTPUT 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION150.00 KILOHERTZ 1ST BAND SUPPRESSION AND 200.00 KILOHERTZ 1ST BAND SUPPRESSION 1ST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION150.00 KILOHERTZ 2ND BAND SUPPRESSION AND 200.00 KILOHERTZ 2ND BAND SUPPRESSION 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION150.00 KILOHERTZ 3RD BAND SUPPRESSION AND 200.00 KILOHERTZ 3RD BAND SUPPRESSION 3RD FUNCTION
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 1ST BAND SUPPRESSION 1ST FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 2ND BAND SUPPRESSION 2ND FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 3RD BAND SUPPRESSION 3RD FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST BAND SUPPRESSION 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND BAND SUPPRESSION 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD BAND SUPPRESSION 3RD FUNCTION
OVERALL LENGTH8.000 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST BAND SUPPRESSION 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD BAND SUPPRESSION 3RD FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND BAND SUPPRESSION 2ND FUNCTION
REFERENCE FREQUENCY PER FUNCTION175.0 KILOHERTZ 3RD BAND SUPPRESSION 3RD FUNCTION
REFERENCE FREQUENCY PER FUNCTION175.0 KILOHERTZ 1ST BAND SUPPRESSION 1ST FUNCTION
REFERENCE FREQUENCY PER FUNCTION175.0 KILOHERTZ 2ND BAND SUPPRESSION 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST BAND SUPPRESSION 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD BAND SUPPRESSION 3RD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND BAND SUPPRESSION 2ND FUNCTION
SPECIAL FEATURESTHREE FILTERED FUNCTIONS; ONE UNFILTERED FUNCTION
SPECIFICATION/STANDARD DATA30003-1185AS156 MANUFACTURERS SPECIFICATION CONTROL
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION100.00 KILOHERTZ 2ND BAND SUPPRESSION AND 150.00 KILOHERTZ 2ND BAND SUPPRESSION AND 200.00 KILOHERTZ 2ND BAND SUPPRESSION AND 250.00 KILOHERTZ 2ND BAND SUPPRESSION 2ND FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION100.00 KILOHERTZ 1ST BAND SUPPRESSION AND 150.00 KILOHERTZ 1ST BAND SUPPRESSION AND 200.00 KILOHERTZ 1ST BAND SUPPRESSION AND 250.00 KILOHERTZ 1ST BAND SUPPRESSION 1ST FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION100.00 KILOHERTZ 3RD BAND SUPPRESSION AND 150.00 KILOHERTZ 3RD BAND SUPPRESSION AND 200.00 KILOHERTZ 3RD BAND SUPPRESSION AND 250.00 KILOHERTZ 3RD BAND SUPPRESSION 3RD FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
UNTHREADED MOUNTING HOLE DIAMETER0.172 INCHES NOMINAL