PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
PROPRIETARY CHARACTERISTICS | PACS |
MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE |
OPERATING TEMP RANGE | -55.0/+85.0 DEG CELSIUS |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
OVERALL HEIGHT | 2.110 INCHES NOMINAL |
OVERALL LENGTH | 3.723 INCHES MAXIMUM |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE50.0 OHMS 2ND RADIO INTERFERENCE |
SPECIAL FEATURES | TWO FILTERED FUNCTIONS |
STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES |
UNTHREADED MOUNTING HOLE DIAMETER | 0.123 INCHES MINIMUM AND 0.147 INCHES MAXIMUM |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.795 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.500 INCHES NOMINAL |
BODY HEIGHT | 1.095 INCHES MINIMUM AND 1.155 INCHES MAXIMUM |
BODY LENGTH | 2.785 INCHES MAXIMUM |
BODY MATERIAL | METAL |
BODY WIDTH | 2.385 INCHES MINIMUM AND 2.415 INCHES MAXIMUM |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, PLUG INPUT 1ST FUNCTION2 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE50.0 OHMS 2ND RADIO INTERFERENCE |
INCLOSURE TYPE | ENCASED |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 1ST RADIO INTERFERENCE60.0 2ND RADIO INTERFERENCE |