Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
2446023094OCEAN TECHNOLOGY INC
RF14047A13619EMS DEVELOPMENT CORPORATION


Techincal Specification:
BODY HEIGHT1.750 INCHES NOMINAL
BODY LENGTH7.870 INCHES NOMINAL
BODY MATERIALMETAL
BODY SURFACE TREATMENTCADMIUM
BODY WIDTH5.370 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION1 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
OVERALL HEIGHT4.000 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY12 CAPTIVE SCREWS
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.190 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS30.0 1ST RADIO INTERFERENCE 1ST FUNCTION30.0 2ND RADIO INTERFERENCE 2ND FUNCTION30.0 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING TEMP RANGE-10.0 TO 65.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 1ST RADIO INTERFERENCE 1ST FUNCTION60.0 2ND RADIO INTERFERENCE 2ND FUNCTION60.0 3RD RADIO INTERFERENCE 3RD FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
SPECIAL FEATURESTHREE FILTERED FUNCTIONS
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES