5935-01-358-0845 CONNECTOR,RECEPTACLE,ELECTRICAL Index 5915-01-358-0847 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-358-0846

Federal Supply Class:
5915

National Item Identification Number:
013580846

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
30241465628CAES SYSTEMS LLC
330396-10181413BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.


Techincal Specification:
AVERAGE LIFE RATING IN HOURS20000.0
BODY HEIGHT0.500 INCHES NOMINAL
BODY LENGTH0.800 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH0.400 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM BLANK AND 60.0 MAXIMUM BLANK
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.360 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION1.98 GIGAHERTZ BLANK AND 2.66 GIGAHERTZ BLANK
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 BLANK
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
OVERALL LENGTH1.650 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.086 INCHES
OPERATING TEMP RANGE-40.0 TO 95.0 CELSIUS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK
REFERENCE FREQUENCY PER FUNCTION1.35 GIGAHERTZ BLANK
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
SPECIAL FEATURESUNPACKAGED UNIT WEIGHT: OZ1.500
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.70 GIGAHERTZ BLANK AND 1.98 GIGAHERTZ BLANK AND 2.66 GIGAHERTZ BLANK AND 4.01 GIGAHERTZ BLANK
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION1.98 GIGAHERTZ BLANK AND 2.66 GIGAHERTZ BLANK
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK