5920-01-195-7253 FUSEHOLDER,EXTRACTOR POST Index 4540-01-195-7255 HEATING ELEMENT,ELECTRICAL,NONIMMERSION TYPE

National Stock Number:
5920-01-195-7254

Federal Supply Class:
5920

National Item Identification Number:
011957254

Description:
FUSE,CARTRIDGE

Detail:
A fuse in which the element is inclosed in a cylindrical body. The element may be renewable. The terminals may be of varying types. It may contain a visual indication that the fusible element is severed, and may also provide an audible alarm through auxiliary circuitry. For noncylindrical items, see FUSE, INCLOSED LINK.


Manufacturer Information:
113203-194271LOCKHEED MARTIN CORP
A-A-5549458536FEDERAL COMMERCIAL ITEM DESCRIPTION PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC
L0341216236DLA LAND AND MARITIME DBA ENGINEERING AND TECHNICAL SUPPORT DIV DOCUMENT STANDARDIZATION DIVISION (VENDOR ITEM DRAWINGS)
LO341216236DLA LAND AND MARITIME DBA ENGINEERING AND TECHNICAL SUPPORT DIV DOCUMENT STANDARDIZATION DIVISION (VENDOR ITEM DRAWINGS)
AA5549458536FEDERAL COMMERCIAL ITEM DESCRIPTION PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC
AA55494-00858536FEDERAL COMMERCIAL ITEM DESCRIPTION PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC
SF25X4059993INTERNATIONAL RECTIFIER CORPORATION USE CAGE CODE 81483 FOR CATALOGING
SF25X4081483INFINEON TECHNOLOGIES AMERICAS CORP


Techincal Specification:
BODY STYLEHOLE TYPE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.488 INCHES NOMINAL
CIRCUIT OVER-CURRENT INTERRUPTION TYPENORMAL INSTANTANEOUS
CONTINUOUS CURRENT RATING IN AMPS35.000
CRITICALITY CODE JUSTIFICATIONFEAT
FEATURES PROVIDEDNONRENEWABLE FUSIBLE ELEMENT
INTERRUPTION INDICATOR METHODOPAQUE BODY
OVERALL DIAMETER0.812 INCHES NOMINAL
OVERALL LENGTH3.188 INCHES NOMINAL
MAXIMUM VOLTAGE RATING IN VOLTS250.0 AC AND 210.0 DC
MOUNTING SLOT WIDTH0.406 INCHES NOMINAL
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICSREFERENCE NUMBER DIFFERENTIATING MATERIAL WILL BE IN ACCORDANCE WITH NAVAL INVENTORY CONTROL POINT ACTIVITY HX QUALITY CONTROL. MANUFACTURING AND TESTING SPECIFICATIONS AVAILABLE AT THE DLA ICP
SPECIAL FEATURESITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE SUPPLY CENTER COLUMBUS PRODUCTION STANDARD NO. LO3412
SURFACE TREATMENTNICKEL TERMINAL
TERMINAL THICKNESS0.125 INCHES NOMINAL


Click here to Register for Free 30-day Trial