ACTUATOR FUNCTION | TRIP-RESET |
CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | EXPLOSION PROOF |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 15.0 AC AND 28.0 DC AND 30.0 DC SINGLE LOCATION |
OVERALL HEIGHT | 2.000 INCHES NOMINAL |
OVERALL LENGTH | 2.188 INCHES NOMINAL |
OVERALL WIDTH | 0.750 INCHES NOMINAL |
MATERIAL | PLASTIC CASE |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC AND 10.0 AMPERES DC SINGLE LOCATION |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 3000.0 AC AND 3000.0 DC SINGLE LOCATION |
MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
POLE QUANTITY | 1 |
RESET METHOD | MANUAL |
SPECIAL FEATURES | FLUORESCENT BUTTON RING |
TERMINAL TYPE AND QUANTITY | 2 SCREW |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 600.000 NOMINAL AT 150 PCT AND 15.000 MINIMUM AT 200 PCT AND 45.000 MAXIMUM AT 200 PCT AND 6.000 NOMINAL AT 300 PCT SINGLE LOCATION |
TRIP RELEASE AMBIENT TEMP RATING | 40.0 CELSIUS NOMINAL SINGLE LOCATION |
TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 SINGLE LOCATION |