5925-00-752-6908 CIRCUIT BREAKER Index 5905-00-752-6912 RESISTOR,FIXED,WIRE WOUND

National Stock Number:
5925-00-752-6909

Federal Supply Class:
5925

National Item Identification Number:
007526909

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
105229R9189346NAVISTAR INTL CORP TRUCK BR OHIO PLANT
5925007526909SCY13E.C.A ETABLISSEMENT CENTRALD'APPROVISIONNEMENT DES FORCES ARMEE
752690919207U S ARMY TANK AUTOMOTIVE COMMAND AMSTA-IM-MM
C9115-1-3072447DANA COMMERCIAL VEHICLE MANUFACTURING, LLC
C9115-1-3082647SENSATA TECHNOLOGIES, INC.
C9115-1-3095019DANA CORP SPICER TRANSMISSION DIV
KC694456442DIAMOND REO TRUCK CO


Techincal Specification:
BODY HEIGHT1.547 INCHES NOMINAL
BODY LENGTH1.828 INCHES NOMINAL
BODY STYLESINGLE POLE TYPE
BODY WIDTH1.312 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.844 INCHES NOMINAL
CIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.574 INCHES NOMINAL
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDVAPORTIGHT
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATION
MATERIALPLASTIC CASE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE30.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS900.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS30.0 DC SINGLE LOCATION
POLE QUANTITY1
RESET METHODAUTOMATIC
TERMINAL TYPE AND QUANTITY2 CLIP
TRIP RELEASE AMBIENT TEMP RATING25.0 CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATION
TRIP RELEASE METHODTHERMAL SINGLE LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT30.000 NOMINAL AT 200 PCT SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER0.174 INCHES NOMINAL