5935-00-963-4040 CONNECTOR,PLUG,ELECTRICAL Index 5925-00-963-4043 CIRCUIT BREAKER

National Stock Number:
5925-00-963-4042

Federal Supply Class:
5925

National Item Identification Number:
009634042

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
107-205-10477342TE CONNECTIVITY CORPORATION
501-205-10379405WOOD ELECTRIC OPERATIONS POTTER AND BRUMFIELD DIV AMF INC
613540-177342TE CONNECTIVITY CORPORATION


Techincal Specification:
ACTUATOR FUNCTIONTRIP-RESET
ARC QUENCHING METHODAIR
CIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDEXPLOSION PROOF
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS200.0 AC AND 28.0 DC SINGLE LOCATION
OVERALL HEIGHT0.750 INCHES NOMINAL
OVERALL LENGTH2.337 INCHES NOMINAL
OVERALL WIDTH1.094 INCHES NOMINAL
MATERIALPLASTIC CASE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE15.0 AMPERES AC AND 15.0 AMPERES DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING
NOMINAL THREAD SIZE0.469 INCHES
POLE QUANTITY1
RESET METHODMANUAL
SPECIFICATION/STANDARD DATA36659-613540-1 MANUFACTURERS SPECIFICATION
TERMINAL TYPE AND QUANTITY2 SCREW
THREAD SERIES DESIGNATORUNS
THREAD QUANTITY PER INCH32
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT60.000 MINIMUM AT 150 PCT AND 900.000 MAXIMUM AT 150 PCT AND 18.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT AND 6.000 MINIMUM AT 300 PCT AND 20.000 MAXIMUM AT 300 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING25.0 CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTICINSTANTANEOUS AND TIME DELAY SINGLE LOCATION
TRIP RELEASE METHODTHERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT116.0 SINGLE LOCATION