5925-01-043-4335 CIRCUIT BREAKER Index 5925-01-043-4337 CIRCUIT BREAKER

National Stock Number:
5925-01-043-4336

Federal Supply Class:
5925

National Item Identification Number:
010434336

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
4001-001-1V76374SAFRAN ELECTRICAL & POWER USA, LLC
4001-01-1V76374SAFRAN ELECTRICAL & POWER USA, LLC
AS220730U583SAE INTERNATIONAL
AS580910U583SAE INTERNATIONAL
AS5809181343SOCIETY OF AUTOMOTIVE ENGINEERS INC
AS2207381343SOCIETY OF AUTOMOTIVE ENGINEERS INC
MS22073-1V0U583SAE INTERNATIONAL
SAE-AS580910U583SAE INTERNATIONAL
MS22073-1V81343SOCIETY OF AUTOMOTIVE ENGINEERS INC
MS2207381343SOCIETY OF AUTOMOTIVE ENGINEERS INC
MIL-C-580981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MS22073-1V96906MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT POLE ONE
BODY LENGTH0.780 INCHES MAXIMUM
BODY STYLESINGLE POLE TYPE
BODY WIDTH0.593 INCHES MAXIMUM
BUSHING LENGTH0.273 INCHES MINIMUM AND 0.293 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.672 INCHES MINIMUM AND 0.734 INCHES MAXIMUM
CIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDCORROSION RESISTANT AND DUSTPROOF AND EXPLOSION PROOF AND FUNGUS RESISTANT AND MOISTURE RESISTANT AND SAND RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY1 PUSH-PULL
MATERIALPLASTIC CASE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE1.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE1.812 INCHES MAXIMUM
NOMINAL THREAD SIZE0.469 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS28.0 DC SINGLE LOCATION
POLE QUANTITY1
RESET METHODMANUAL
SPECIFICATION/STANDARD DATA81343-MS22073 PROFESSIONAL/INDUSTRIAL ASSOCIATION SPECIFICATION
TERMINAL TYPE AND QUANTITY2 SCREW
THREAD SERIES DESIGNATORUNS
THREAD QUANTITY PER INCH32
TRIP RELEASE AMBIENT TEMP RATING25.0 CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATION
TRIP RELEASE METHODTHERMAL SINGLE LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT145.0 SINGLE LOCATION


Click here to Register for Free 30-day Trial