3020-01-054-3193 GEAR ASSEMBLY,WORM Index 5925-01-054-3196 CIRCUIT BREAKER

National Stock Number:
5925-01-054-3195

Federal Supply Class:
5925

National Item Identification Number:
010543195

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
P2XAM1516MG3-80 125V60HZ74193EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV


Techincal Specification:
BODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
MANUAL ACTUATOR TYPE AND QUANTITY2 TOGGLE
BOSS HEIGHT0.156 INCHES NOMINAL
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND MOISTURE RESISTANT
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.750 INCHES NOMINAL
ACTUATOR FUNCTIONTRIP-RESET
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE80.0 AMPERES AC ALL LOCATIONS
NOMINAL THREAD SIZE0.138 INCHES
BODY LENGTH3.719 INCHES NOMINAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
TRIP RELEASE METHODMAGNETIC-HYDRAULIC ALL LOCATIONS
CASE MATERIALPLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH3.063 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY4 THREADED STUD
FRAGILITY FACTORMODERATELY RUGGED
THREAD SERIES DESIGNATORUNC
CIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH1.031 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
TRIP RELEASE CHARACTERISTICINSTANTANEOUS ALL LOCATIONS
RESET METHODMANUAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS125.0 AC ALL LOCATIONS
BODY WIDTH2.031 INCHES NOMINAL
ACTUATOR POSITION DESIGNATIONAT EACH POLE
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS
FREQUENCY IN HERTZ60.0 ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.031 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE AND TWO LINKED
MOUNTING SURFACE TO TERMINAL END DISTANCE3.239 INCHES NOMINAL
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
THREAD QUANTITY PER INCH32
POLE QUANTITY2
ARC QUENCHING METHODAIR
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS2000.0 AC ALL LOCATIONS