5925-01-122-1523 CIRCUIT BREAKER Index 5330-01-122-1525 RETAINER,PACKING

National Stock Number:
5925-01-122-1524

Federal Supply Class:
5925

National Item Identification Number:
011221524

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
29-1217615-307397GENERAL DYNAMICS ADVANCED INFORMATION SYSTEMS INC. DBA GENERAL DYNAMICS ADVANCED INFORMATION SYSTEMS
AP411-1R5676-181541SENSATA TECHNOLOGIES MARYLAND, INC


Techincal Specification:
TRIP RELEASE METHODMAGNETIC ALL LOCATIONS
FREQUENCY IN HERTZ60.0 ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS300.0 AC SECOND LOCATION
POLE QUANTITY3
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE20.0 AMPERES AC SECOND LOCATION
20.0 AMPERES AC THIRD LOCATION
CIRCUIT PROTECTION TYPEOVERVOLTAGE FIRST LOCATION
TERMINAL TYPE AND QUANTITY6 WIRE HOOK AND
2 QUICK DISCONNECT, MALE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS115.0 AC FIRST LOCATION
250.0 AC SECOND LOCATION
250.0 AC THIRD LOCATION
TRIP RELEASE CHARACTERISTICINSTANTANEOUS FIRST LOCATION
TIME DELAY SECOND LOCATION
TIME DELAY THIRD LOCATION
RESET METHODMANUAL
BODY STYLEMULTIPOLE-SINGLE ACTUATOR TYPE
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING W/PANEL SEAL
300.0 AC THIRD LOCATION
INTERNAL TRIP RELEASE CONFIGURATIONRELAY TRIP FIRST LOCATION
SERIES TRIP SECOND LOCATION
SERIES TRIP THIRD LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.500 MINIMUM AT 200 PCT AND
9.000 MAXIMUM AT 200 PCT SECOND LOCATION
0.500 MINIMUM AT 200 PCT AND
9.000 MAXIMUM AT 200 PCT THIRD LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT115.0 ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
BUSHING LENGTH0.332 INCHES MINIMUM AND
0.375 INCHES MAXIMUM
BODY LENGTH1.500 INCHES MAXIMUM
BODY WIDTH1.875 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.844 INCHES MINIMUM AND
0.906 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.595 INCHES MINIMUM AND
0.656 INCHES MAXIMUM
MOUNTING SURFACE TO TERMINAL END DISTANCE1.780 INCHES MAXIMUM
THREAD SERIES DESIGNATORUNEF
NOMINAL THREAD SIZE0.375 INCHES
THREAD QUANTITY PER INCH32
MANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT POLE TWO
AUXILIARY SWITCH FUNCTION AND QUANTITY1 ALARM
SWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE THREE
SWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS0.5 AC
SWITCH VOLTAGE RATING AND TYPE IN VOLTS125.0 AC
SWITCH TERMINAL TYPEQUICK DISCONNECT, MALE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDHERMETICALLY SEALED AND
MOISTURE RESISTANT AND
SALT SPRAY PROOF AND
SHOCKPROOF AND
VIBRATIONPROOF
NONTURN DEVICE DIAMETER0.250 INCHES NOMINAL
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
SPECIAL FEATURESNO CURRENT ON POLE ONE