BODY LENGTH | 0.780 INCHES NOMINAL |
BODY STYLE | SINGLE POLE TYPE |
BODY WIDTH | 0.593 INCHES NOMINAL |
BUSHING LENGTH | 0.250 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.593 INCHES NOMINAL |
CIRCUIT PROTECTION TYPE | OVERVOLTAGE ALL LOCATIONS |
FREQUENCY IN HERTZ | 380.0 OR 420.0 ALL LOCATIONS |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES DC ALL LOCATIONS |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000.0 AC AND 2000.0 DC ALL LOCATIONS |
MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.525 INCHES NOMINAL |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 115.0 AC AND 28.0 DC ALL LOCATIONS |
POLE QUANTITY | 4 |
RESET METHOD | MANUAL |
SPECIFICATION/STANDARD DATA | 96906-MS26574 GOVERNMENT STANDARD |
TERMINAL TYPE AND QUANTITY | 2 SCREW |
TRIP RELEASE AMBIENT TEMP RATING | 71.0 FAHRENHEIT MAXIMUM ALL LOCATIONS |
TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
TRIP RELEASE METHOD | THERMAL ALL LOCATIONS |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 3600.000 NOMINAL AT 130 PCT ALL LOCATIONS |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 130.0 ALL LOCATIONS |