5925-01-312-3375 CIRCUIT BREAKER Index 5925-01-312-3377 CIRCUIT BREAKER

National Stock Number:
5925-01-312-3376

Federal Supply Class:
5925

National Item Identification Number:
013123376

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
302-97-00858475L-3 COMMUNICATIONS WESTWOOD CORPORATION
302-99-00858475L-3 COMMUNICATIONS WESTWOOD CORPORATION
702-S013456623MICROSEMI CORP.-POWER MANAGEMENT GROUP
706380 PIECE 7358475L-3 COMMUNICATIONS WESTWOOD CORPORATION
706381 PIECE 7358475L-3 COMMUNICATIONS WESTWOOD CORPORATION
SM600BA10A1281640SAFRAN POWER USA, LLC


Techincal Specification:
CASE MATERIALPLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.530 INCHES MAXIMUM
FRAGILITY FACTORMODERATELY RUGGED
FREQUENCY IN HERTZ400.0 SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE10.0 AMPERES AC SINGLE LOCATION AND 10.0 AMPERES DC SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF
POLE QUANTITY1
PROPRIETARY CHARACTERISTICSPACS
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE4.260 INCHES MAXIMUM
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS115.0 AC SINGLE LOCATION AND 28.0 DC SINGLE LOCATION
OVERALL LENGTH3.250 INCHES MAXIMUM
RESET METHODAUTOMATIC
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
SWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE ONE
SWITCH TERMINAL TYPEPIN
SWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
TERMINAL TYPE AND QUANTITY2 THREADED STUD
TRIP RELEASE METHODMAGNETIC SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER0.167 INCHES MINIMUM AND 0.177 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.940 INCHES NOMINAL
ARC QUENCHING METHODMAGNETIC BLOWOUT
AUXILIARY SWITCH FUNCTION AND QUANTITY1 ALARM
BODY STYLESINGLE POLE TYPE
BODY WIDTH1.200 INCHES MAXIMUM


Click here to Register for Free 30-day Trial