5310-01-339-1439 WASHER,FLAT Index 5925-01-339-1441 CIRCUIT BREAKER

National Stock Number:
5925-01-339-1440

Federal Supply Class:
5925

National Item Identification Number:
013391440

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
R11-2-3.00A-B1253N581POCO SALES
R11-2-3.00A-B12581541SENSATA TECHNOLOGIES MARYLAND, INC
R11-2-3.00A-B125EV81541SENSATA TECHNOLOGIES MARYLAND, INC
R11-2-3.00A-B1258F388SPECTROL ELECTRONICS CORP RUSSELL F CLARK CO INC REPRESENTIVE


Techincal Specification:
POLE QUANTITY1
PROPRIETARY CHARACTERISTICSPACS
MOUNTING FACILITY TYPE AND QUANTITY2 CLIP
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS250.0 AC SINGLE LOCATION
RESET METHODMANUAL
SPECIAL FEATURES1,LED IS PROVIDED IN ROCKER HANDLE; CONNECTION VIA COLOR CODED LEADS
TERMINAL TYPE AND QUANTITY2 QUICK DISCONNECT, MALE
TRIP RELEASE CHARACTERISTICINSTANTANEOUS SINGLE LOCATION
TRIP RELEASE DUTY CYCLECONTINUOUS SINGLE LOCATION
TRIP RELEASE METHODMAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT750.0 SINGLE LOCATION
ACTUATOR FUNCTIONTRIP-RESET
BODY HEIGHT1.438 INCHES NOMINAL
BODY LENGTH1.500 INCHES NOMINAL
BODY STYLESINGLE POLE TYPE
BODY WIDTH0.781 INCHES NOMINAL
BOSS HEIGHT0.125 INCHES NOMINAL
CASE MATERIALPLASTIC
CIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ60.0 SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE3.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1000.0 AC SINGLE LOCATION