ACTUATOR FUNCTION | TRIP-RESET |
ACTUATOR POSITION DESIGNATION | AT POLE TWO |
BODY LENGTH | 1.562 INCHES MAXIMUM |
BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
BODY WIDTH | 1.937 INCHES MAXIMUM |
BUSHING LENGTH | 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.906 INCHES MAXIMUM |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.625 INCHES NOMINAL |
CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
FEATURES PROVIDED | HIGH INRUSH PROTECTION |
FRAGILITY FACTOR | MODERATELY RUGGED |
FREQUENCY IN HERTZ | 50.0 OR 60.0 FIRST LOCATION |
FREQUENCY IN HERTZ | 50.0 OR 60.0 SECOND LOCATION |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HERMETICALLY SEALED AND SHOCKPROOF AND VIBRATIONPROOF |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 500.0 MILLIAMPERES AC SECOND LOCATION |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 500.0 MILLIAMPERES AC FIRST LOCATION |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 1.5 AMPERES DC THIRD LOCATION |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 300.0 AC AND 500.0 DC ALL LOCATIONS |
MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.950 INCHES MAXIMUM |
NOMINAL THREAD SIZE | 0.375 INCHES |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC FIRST LOCATION |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC SECOND LOCATION |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 50.0 DC THIRD LOCATION |
POLE QUANTITY | 3 |
RESET METHOD | MANUAL |
SPECIAL HANDLING FEATURE | MAGNETIC |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
TERMINAL TYPE AND QUANTITY | 6 SCREW |
THREAD SERIES DESIGNATOR | UNEF |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.055 MINIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT FIRST LOCATION |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.055 MINIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT SECOND LOCATION |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.060 MINIMUM AT 200 PCT AND 0.600 MAXIMUM AT 200 PCT THIRD LOCATION |
TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
UNPACKAGED UNIT WEIGHT | 5.400 OUNCES NOMINAL |