BODY STYLE | SINGLE POLE TYPE |
BUSHING LENGTH | 0.400 INCHES NOMINAL |
CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH BUTTON |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC SINGLE LOCATION |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC SINGLE LOCATION |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.660 INCHES NOMINAL |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC AND 50.0 DC SINGLE LOCATION |
POLE QUANTITY | 1 |
RESET METHOD | MANUAL |
TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 5.000 MINIMUM AT 200 PCT AND 30.000 MAXIMUM AT 200 PCT TENTH LOCATION |