5925-01-552-3030 CIRCUIT BREAKER Index 2590-01-552-3032 SHOE,JACK-SUPPORT

National Stock Number:
5925-01-552-3031

Federal Supply Class:
5925

National Item Identification Number:
015523031

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
AS220740U583SAE INTERNATIONAL
AS2207481343SOCIETY OF AUTOMOTIVE ENGINEERS INC
AS22074-10U583SAE INTERNATIONAL
MS22074-10U583SAE INTERNATIONAL
SAE-AS580910U583SAE INTERNATIONAL
AS22074-181343SOCIETY OF AUTOMOTIVE ENGINEERS INC


Techincal Specification:
BODY LENGTH1.187 INCHES NOMINAL
BODY STYLESINGLE POLE TYPE
BODY WIDTH0.750 INCHES NOMINAL
BUSHING LENGTH0.250 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.650 INCHES NOMINAL
CIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
PART NAME ASSIGNED BY CONTROLLING AGENCYCIRCUIT BREAKER, RECYCLING, TRIP FREE, PUSH-PULL, 1/2 THRU 5 AMPERE, TYPE 1
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE1.812 INCHES NOMINAL
NOMINAL THREAD SIZE0.469 INCHES
POLE QUANTITY1
RESET METHODMANUAL
TERMINAL TYPE AND QUANTITY2 SCREW
THREAD SERIES DESIGNATORUNS
THREAD QUANTITY PER INCH32
TRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATION
TRIP RELEASE METHODMAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT110.0 SINGLE LOCATION