5925-14-384-6035 CIRCUIT BREAKER Index 5310-14-384-8724 NUT,SELF-LOCKING,ROUND

National Stock Number:
5925-14-384-6037

Federal Supply Class:
5925

National Item Identification Number:
143846037

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
84311015F0282CROUZET SA
84311015F9111THALES AVS FRANCE SAS
84311015FA0X2CROUZET


Techincal Specification:
ACTUATOR FUNCTIONRESET
CASE MATERIALPLASTIC
CIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ400.0 ALL LOCATIONS
MANUAL ACTUATOR TYPE AND QUANTITY1 PUSH BUTTON
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE15.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS2000.0 AC ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDGENERAL PURPOSE
POLE QUANTITY3
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS120.0 AC ALL LOCATIONS
RESET METHODMANUAL
SPECIAL FEATURESCIRCUIT PROTECTION TYPE CAN ALSO BE OVER-VOLTAGE,CANON DE MONTAGE DIA.12MM,ANTI-DEFLAGRANT,LONG 46MM,LARG 20MM,HAUT 48.7MM
TERMINAL TYPE AND QUANTITY6 SCREW
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.300 MINIMUM AT 500 PCT SECOND LOCATION AND 0.900 MAXIMUM AT 500 PCT SECOND LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.080 MINIMUM AT 1000 PCT THIRD LOCATION AND 0.220 MAXIMUM AT 1000 PCT THIRD LOCATION
TRIP RELEASE AMBIENT TEMP RATING25.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
TRIP RELEASE METHODTHERMAL ALL LOCATIONS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT4.000 MINIMUM AT 300 PCT FIRST LOCATION AND 10.000 MAXIMUM AT 300 PCT FIRST LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT138.0 ALL LOCATIONS
ULTIMATE TRIP TIME PER POLE IN SECONDS0.080 MINIMUM ALL LOCATIONS AND 10.000 MAXIMUM ALL LOCATIONS