6605-00-072-4895 CONSOLE,COMPUTER TE Index 5950-00-072-4897 COIL,ELECTRICAL

National Stock Number:
5930-00-072-4896

Federal Supply Class:
5930

National Item Identification Number:
000724896

Description:
SWITCH,THERMOSTATIC

Detail:
A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).


Manufacturer Information:
1JH2801PIECE9211660WESTINGHOUSE ELECTRIC CORP CONTROL BUSINESS UNIT
222-10NN222122419278DETROIT SWITCH INC


Techincal Specification:
STYLE DESIGNATORRECTANGULAR
OVERALL LENGTH5.375 INCHES NOMINAL
OVERALL HEIGHT3.625 INCHES NOMINAL
OVERALL WIDTH2.688 INCHES NOMINAL
BODY HEIGHT2.500 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CONTACT ACTION STIMULUSINCREASE
CONTACT ADJUSTABILITYDEACTUATION POINT ADJUSTABLE AND
ACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT RANGE140.00 TO 215.00 ACTUATION POINT DEGREES FAHRENHEIT AND
128.00 TO 203.00 DEACTUATION POINT DEGREES FAHRENHEIT
CONTACT ADJUSTMENT TYPEEXTERNAL DEACTUATION POINT SCREW AND
EXTERNAL ACTUATION POINT SCREW
CONTACT VOLTAGE RATING IN VOLTS550.0 AC AT SEA LEVEL FIRST VOLTAGE
115.0 AC AT SEA LEVEL SECOND VOLTAGE
550.0 DC AT SEA LEVEL THIRD VOLTAGE
115.0 DC AT SEA LEVEL FOURTH VOLTAGE
CONTACT LOAD CURRENT RATING3.2 AMPERES RESISTIVE LOAD FIRST VOLTAGE
16.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
2.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE
9.6 AMPERES RESISTIVE LOAD FOURTH VOLTAGE
OPERATING TEMP RATING-30.0 DEG FAHRENHEIT MINIMUM AND
245.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNEDGAS
TEMP SENSING ELEMENT TYPECAPILLARY TUBE-BULB
CAPILLARY TUBE LENGTH120.0 INCHES NOMINAL
BULB LENGTH6.000 INCHES NOMINAL
BULB DIAMETER1.125 INCHES NOMINAL
TERMINAL TYPESCREW
MOUNTING METHODBRACKET AND
UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER0.281 INCHES NOMINAL
MOUNTING FACILITY PATTERNISOSCELES TRIANGLE
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS2.406 INCHES NOMINAL
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS1.750 INCHES NOMINAL
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS3.281 INCHES NOMINAL
FEATURES PROVIDEDTUBING END SEAL CONNECTION
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONDUSTPROOF AND
WATERTIGHT
PRECIOUS MATERIALSILVER
PRECIOUS MATERIAL AND LOCATIONCONTACTS SILVER


Click here to Register for Free 30-day Trial