Description:
SWITCH,THERMOSTATIC

Detail:
A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).


Manufacturer Information:
2620527-210001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
VE208493929RADIODETECTION, LLC


Techincal Specification:
STYLE DESIGNATORRECTANGULAR W/BRACKET
OVERALL LENGTH1.250 INCHES NOMINAL
OVERALL HEIGHT0.690 INCHES MAXIMUM
OVERALL WIDTH0.380 INCHES NOMINAL
BODY LENGTH0.750 INCHES NOMINAL
BODY WIDTH0.340 INCHES NOMINAL
BODY HEIGHT0.440 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CONTACT ACTION STIMULUSINCREASE
CONTACT ADJUSTABILITYDEACTUATION POINT ADJUSTABLE, PRESET AND
ACTUATION POINT ADJUSTABLE, PRESET
CONTACT ADJUSTMENT RANGE0.00 TO 55.00 ACTUATION POINT DEGREES CELSIUS AND
0.00 TO 55.00 DEACTUATION POINT DEGREES CELSIUS
CONTACT ADJUSTMENT TYPEEXTERNAL DEACTUATION POINT SCREW AND
EXTERNAL ACTUATION POINT SCREW
CONTACT STIMULUS RATING45.00 ACTUATION POINT NOMINAL DEGREES CELSIUS AND
42.00 DEACTUATION POINT NOMINAL DEGREES CELSIUS AND
3.00 DIFFERENTIAL POINT NOMINAL DEGREES CELSIUS
CONTACT VOLTAGE RATING IN VOLTS230.0 AC AT SEA LEVEL FIRST VOLTAGE
32.0 DC AT SEA LEVEL SECOND VOLTAGE
FREQUENCY IN HERTZ60.0 FIRST VOLTAGE
CONTACT LOAD CURRENT RATING1.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE
1.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
MEDIA FOR WHICH DESIGNEDGAS OR
LIQUID
TEMP SENSING ELEMENT TYPEINTERNAL SENSOR
TERMINAL TYPETAB, SOLDER LUG
MOUNTING METHODBRACKET AND
SLOT
MOUNTING SLOT WIDTH0.120 INCHES NOMINAL
MOUNTING FACILITY PATTERNTWO POSITION IN-LINE
DISTANCE BETWEEN MOUNTING FACILITY CENTERS1.000 INCHES NOMINAL