5930-00-259-8966 SWITCH,ROTARY Index 5999-00-259-8975 CONTACT,ELECTRICAL

National Stock Number:
5930-00-259-8974

Federal Supply Class:
5930

National Item Identification Number:
002598974

Description:
SWITCH,THERMOSTATIC

Detail:
A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).


Manufacturer Information:
22062019278DETROIT SWITCH INC
222-10NL19278DETROIT SWITCH INC
51MCD1221N2REVAPC1310855CARRIER CORP
222-10NL-222112819278DETROIT SWITCH INC
222NL222112819278DETROIT SWITCH INC
55500-5900-871174ALT4PC0-60DEG80064NAVAL SHIP SYSTEMS COMMAND
TS1215ALT4PC0-60DEG19278DETROIT SWITCH INC
X2310219278DETROIT SWITCH INC
569-5901-1192373REVAPC1380064NAVAL SHIP SYSTEMS COMMAND


Techincal Specification:
STYLE DESIGNATORRECTANGULAR
OVERALL LENGTH5.188 INCHES NOMINAL
OVERALL HEIGHT5.625 INCHES NOMINAL
OVERALL WIDTH2.812 INCHES NOMINAL
BODY LENGTH5.000 INCHES NOMINAL
BODY HEIGHT2.750 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CONTACT ACTION STIMULUSINCREASE
CONTACT ADJUSTABILITYACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT RANGE-10.00 TO 60.00 ACTUATION POINT DEGREES FAHRENHEIT
CONTACT ADJUSTMENT TYPEEXTERNAL ACTUATION POINT SCREW
CONTACT VOLTAGE RATING IN VOLTS115.0 AC AT SEA LEVEL FIRST VOLTAGE
230.0 AC AT SEA LEVEL SECOND VOLTAGE
440.0 AC AT SEA LEVEL THIRD VOLTAGE
550.0 AC AT SEA LEVEL FOURTH VOLTAGE
115.0 DC AT SEA LEVEL FIFTH VOLTAGE
230.0 DC AT SEA LEVEL SIXTH VOLTAGE
440.0 DC AT SEA LEVEL SEVENTH VOLTAGE
550.0 DC AT SEA LEVEL EIGHTH VOLTAGE
FREQUENCY IN HERTZ60.0 FIRST VOLTAGE
60.0 SECOND VOLTAGE
60.0 THIRD VOLTAGE
60.0 FOURTH VOLTAGE
CONTACT LOAD CURRENT RATING16.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE
8.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE
4.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE
3.2 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE
9.6 AMPERES INDUCTIVE LOAD FIFTH VOLTAGE
4.8 AMPERES INDUCTIVE LOAD SIXTH VOLTAGE
2.5 AMPERES INDUCTIVE LOAD SEVENTH VOLTAGE
2.0 AMPERES INDUCTIVE LOAD EIGHTH VOLTAGE
MEDIA FOR WHICH DESIGNEDLIQUID
TEMP SENSING ELEMENT TYPECAPILLARY TUBE-BULB
CAPILLARY TUBE LENGTH180.0 INCHES NOMINAL
BULB LENGTH3.000 INCHES NOMINAL
BULB DIAMETER0.375 INCHES NOMINAL
TERMINAL TYPESCREW
MOUNTING METHODBRACKET AND
UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER0.281 INCHES NOMINAL
MOUNTING FACILITY PATTERNISOSCELES TRIANGLE
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS2.406 INCHES NOMINAL
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS0.656 INCHES NOMINAL
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS3.281 INCHES NOMINAL
FEATURES PROVIDEDELECTRICAL ACCESS PORT
PRECIOUS MATERIALSILVER
PRECIOUS MATERIAL AND LOCATIONCONTACTS SILVER


Click here to Register for Free 30-day Trial