5930-00-340-5505 SWITCH SUBASSEMBLY Index 5365-00-340-5514 SHIM

National Stock Number:
5930-00-340-5506

Federal Supply Class:
5930

National Item Identification Number:
003405506

Description:
SWITCH,ROTARY

Detail:
A switch actuated by a definite angular rotation of the switch shaft about its axis. For items having rated actuation travel and pressure characteristics, see SWITCH, SENSITIVE. Excludes RELAY, ROTARY; SWITCH, STEPPING; and SWITCH, TELEPHONE (as modified).


Manufacturer Information:
M-32J994-203538LOCKHEED MARTIN CORPORATION
M-32J994-204009COOPER INDUSTRIES INC COOPER DISTRIBUTION EQUIPMENT DIV


Techincal Specification:
CONTACT VOLTAGE RATING IN VOLTS115.0 AC AT SEA LEVEL
28.0 DC AT SEA LEVEL
CONTACT LOAD CURRENT RATING250.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL
250.0 MILLIAMPERES RESISTIVE LOAD DC AT SEA LEVEL
TERMINAL TYPETAB W/SCREW
SWITCH ACTUATOR INDEXING POSITION QUANTITY6 SINGLE ACTUATOR
STYLE DESIGNATORTAP, CIRCULAR, BUSHING MOUNT
OVERALL LENGTH9.688 INCHES NOMINAL
OVERALL DIAMETER2.812 INCHES NOMINAL
INDIVIDUAL SECTION QUANTITY16
SWITCH CONTACT BASIC DESIGNNONPILE-UP SYMMETRICAL
POLE QUANTITY1 EACH SECTION PERIPHERY
THROW QUANTITY5 EACH SECTION PERIPHERY
CONTACT SWITCHING ACTIONBREAKS BEFORE MAKES EACH SECTION PERIPHERY
SWITCH ACTUATOR STOP DEVICE TYPEADJUSTABLE STOP SINGLE ACTUATOR
SHAFT TYPEROUND, SQUARE, THREADED HOLE SINGLE ACTUATOR
FIRST FLAT LENGTH1.594 INCHES NOMINAL SINGLE ACTUATOR
SHAFT DIAMETER0.312 INCHES NOMINAL SINGLE ACTUATOR
SHAFT LENGTH1.969 INCHES NOMINAL SINGLE ACTUATOR
SQUARE SHAFT SIZE0.250 INCHES NOMINAL SINGLE ACTUATOR
MOUNTING METHODBRACKET AND
THREADED STUD SINGLE MOUNTING FACILITY
THREAD SERIES DESIGNATORUNF SINGLE MOUNTING FACILITY
NOMINAL THREAD SIZE0.190 INCHES SINGLE MOUNTING FACILITY
THREAD CLASS2A SINGLE MOUNTING FACILITY
THREAD LENGTH0.375 INCHES NOMINAL SINGLE MOUNTING FACILITY
MOUNTING FACILITY PATTERNFOUR POSITION RECTANGULAR SINGLE MOUNTING FACILITY
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONDUSTPROOF
OPERATING TEMP RANGE-85.0 TO 185.0 DEG FAHRENHEIT


Click here to Register for Free 30-day Trial