| CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL |
| 28.0 DC AT SEA LEVEL |
| CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD AND |
| 1.0 AMPERES INDUCTIVE LOAD AC AT SEA LEVEL |
| 1.0 AMPERES INDUCTIVE LOAD DC AT SEA LEVEL |
| TERMINAL TYPE | TAB, SOLDER LUG |
| SWITCH ACTUATOR INDEXING POSITION QUANTITY | 3 SINGLE ACTUATOR |
| STYLE DESIGNATOR | TAP, CIRCULAR, BUSHING MOUNT |
| OVERALL LENGTH | 2.496 INCHES NOMINAL |
| OVERALL DIAMETER | 1.155 INCHES MINIMUM AND |
| 1.185 INCHES MAXIMUM |
| INDIVIDUAL SECTION QUANTITY | 2 |
| SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
| ROTOR THROUGH CONNECTION QUANTITY | 2 EACH SECTION |
| POLE QUANTITY | 2 EACH SECTION FRONT |
| THROW QUANTITY | 3 EACH SECTION REAR |
| CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES EACH SECTION REAR |
| SWITCH ACTUATOR POSITIONING INCREMENT | 30.0 DEGREES SINGLE ACTUATOR |
| SWITCH ACTUATOR STOP DEVICE TYPE | FIXED STOP SINGLE ACTUATOR |
| SHAFT TYPE | ROUND, FLATTED SINGLE ACTUATOR |
| FIRST FLAT LENGTH | 0.230 INCHES MINIMUM AND |
| 0.270 INCHES MAXIMUM SINGLE ACTUATOR |
| FLAT HEIGHT | 0.215 INCHES MINIMUM AND |
| 0.223 INCHES MAXIMUM SINGLE ACTUATOR |
| SHAFT DIAMETER | 0.248 INCHES MINIMUM AND |
| 0.251 INCHES MAXIMUM SINGLE ACTUATOR |
| SHAFT LENGTH | 1.150 INCHES NOMINAL SINGLE ACTUATOR |
| NONTURN DEVICE TYPE | SLOTTED BUSHING AT 3:00 O'CLOCK |
| MOUNTING METHOD | THREADED BUSHING W/PANEL SEAL SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNEF SINGLE MOUNTING FACILITY |
| NOMINAL THREAD SIZE | 0.375 INCHES SINGLE MOUNTING FACILITY |
| THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
| THREAD LENGTH | 0.417 INCHES MINIMUM AND |
| 0.457 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| TEST DATA DOCUMENT | 81349-MIL-S-3786/4 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | EXPLOSION PROOF |
| SHAFT FLAT/SLOT ANGULAR LOCATION | 180.0 DEGREES FROM CONTACT POSITION 1 SINGLE ACTUATOR |
| OPERATING TEMP RANGE | -65.0 TO 125.0 DEG CELSIUS |