National Stock Number: 5930-00-503-0236
Federal Supply Class: 5930
National Item Identification Number: 005030236
Description: SWITCH,THERMOSTATIC
Detail: A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
|
Manufacturer Information:
01-17010-0 | 73168 | KIDDE TECHNOLOGIES, INC | 0C218266-3 | 06845 | RAYTHEON COMPANY | 17010 | 73168 | KIDDE TECHNOLOGIES, INC |
|
Techincal Specification:
OVERALL LENGTH | 3.719 INCHES NOMINAL | OVERALL DIAMETER | 0.625 INCHES NOMINAL | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION | CONTACT ACTION STIMULUS | INCREASE | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE, PRESET | CONTACT ADJUSTMENT RANGE | -18.00 TO 200.00 ACTUATION POINT DEGREES CELSIUS | CONTACT STIMULUS RATING | 1.00 DIFFERENTIAL POINT NOMINAL DEGREES CELSIUS | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE | | 28.0 DC AT SEA LEVEL SECOND VOLTAGE | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE | | 2.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE | OPERATING TEMP RATING | 500.0 DEG CELSIUS MAXIMUM AND | | -273.1 DEG CELSIUS MINIMUM | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR | TERMINAL TYPE | WIRE LEAD | MOUNTING METHOD | IMMERSION WELL | TEST DATA DOCUMENT | 81349-MILS7599 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). | THE MANUFACTURERS DATA | | MANUFACTURERS CODE | 06845 | DESIGN CONTROL REFERENCE | 0C218266-3 |
|
|