PRESSURE SWITCH TYPE | DIFFERENTIAL |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
CONTACT ADJUSTMENT RANGE | 50.00 TO 500.00 ACTUATION POINT POUNDS PER SQUARE INCH |
CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT HEX NUT |
CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL SINGLE VOLTAGE |
FREQUENCY IN HERTZ | 60.0 SINGLE VOLTAGE |
CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
PROOF PRESSURE | 575.00 POUNDS PER SQUARE INCH |
TERMINAL TYPE | TAB W/SCREW |
MOUNTING METHOD | BASE |
MOUNTING FACILITY PATTERN | TWO POSITION DIAGONAL |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 4.250 INCHES NOMINAL |
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 2.875 INCHES NOMINAL |
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | MATERIAL WILL BE IN ACCORDANCE WITH SHIPS PARTS CONTROL CENTER ACTIVITY HX QUALITY CONTROL,MANUFACTURING AND TESTING SPECIFICATIONS |
THE MANUFACTURERS DATA | |
MANUFACTURERS CODE | 88234 |
DESIGN CONTROL REFERENCE | J11M0DEL364CLASSG |