5930-00-521-5449 SWITCH,THERMOSTATIC Index 2510-00-521-5457 LEVER

National Stock Number:
5930-00-521-5450

Federal Supply Class:
5930

National Item Identification Number:
005215450

Description:
SWITCH,THERMOSTATIC

Detail:
A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).


Manufacturer Information:
25523158-0145153HAMILTON SUNDSTRAND CORPORATION
25523158-0155820RTX CORPORATION
5-09010-618509PSG CONTROLS, INC.
25523168-0080234VAPOR CORP SUB OF BRUNSWICK CORP
695315-698897LOCKHEED MARTIN CORP
25523158-0199167HAMILTON SUNDSTRAND CORPORATION


Techincal Specification:
STYLE DESIGNATORCYLINDRICAL W/FLANGE
OVERALL LENGTH3.884 INCHES MINIMUM AND
5.219 INCHES MAXIMUM
WIDTH ACROSS FLATS0.688 INCHES MINIMUM AND
1.005 INCHES MAXIMUM
BODY DIAMETER0.390 INCHES MINIMUM AND
0.450 INCHES MAXIMUM
BODY LENGTH2.884 INCHES MINIMUM AND
3.019 INCHES MAXIMUM
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CONTACT ACTION STIMULUSINCREASE
CONTACT ADJUSTABILITYACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATING210.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT
CONTACT VOLTAGE RATING IN VOLTS22.0 DC AT SEA LEVEL FIRST VOLTAGE
30.0 DC AT SEA LEVEL SECOND VOLTAGE
CONTACT LOAD CURRENT RATING5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE
5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
OPERATING TEMP RATING-65.0 DEG FAHRENHEIT MINIMUM AND
475.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNEDGAS
TEMP SENSING ELEMENT TYPEBULB
TERMINAL TYPECONNECTOR, RECEPTACLE
MOUNTING METHODTHREADED BUSHING
THREAD SERIES DESIGNATORUNF SINGLE THREADED BUSHING
NOMINAL THREAD SIZE0.625 INCHES SINGLE THREADED BUSHING
THREAD CLASS2A SINGLE THREADED BUSHING
THREAD QUANTITY PER INCH18 SINGLE THREADED BUSHING
THREAD LENGTH0.530 INCHES MINIMUM AND
0.590 INCHES MAXIMUM SINGLE THREADED BUSHING
FEATURES PROVIDEDAUTOMATIC RESET
SPECIAL FEATURESRECEPTACLE TO HAVE PROVISIONS FOR LOCKWIRING PLUG
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONDUSTPROOF


Click here to Register for Free 30-day Trial