CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE, PRESET |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTMENT RANGE | -100.00 TO 300.00 ACTUATION POINT DEGREES FAHRENHEIT |
CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW |
CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CONTACT LOAD CURRENT RATING | 25.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CONTACT STIMULUS RATING | 0.20 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT |
CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL SECOND VOLTAGE |
MOUNTING METHOD | THREADED BUSHING |
NOMINAL THREAD SIZE | 0.750 INCHES SINGLE THREADED BUSHING |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
OPERATING TEMP RATING | -100.0 FAHRENHEIT MINIMUM AND 700.0 FAHRENHEIT MAXIMUM |
TERMINAL TYPE | WIRE LEAD |
THREAD CLASS | 3A SINGLE THREADED BUSHING |
THREAD LENGTH | 0.188 INCHES NOMINAL SINGLE THREADED BUSHING |
THREAD QUANTITY PER INCH | 14 SINGLE THREADED BUSHING |
THREAD SERIES DESIGNATOR | UNC SINGLE THREADED BUSHING |