5930-00-583-2147 SWITCH,THERMOSTATIC Index 5930-00-583-2149 SWITCH,THERMOSTATIC

National Stock Number:
5930-00-583-2148

Federal Supply Class:
5930

National Item Identification Number:
005832148

Description:
SWITCH,THERMOSTATIC

Detail:
A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).


Manufacturer Information:
222-10NN-222107196452AMERICAN STANDARD INC CONTROLS DEPT PRODUCTS GROUP
222-10NN222107119278DETROIT SWITCH INC
MILC217481349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC221281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY LENGTH4.782 INCHES NOMINAL
BULB DIAMETER1.125 INCHES NOMINAL
BULB LENGTH6.000 INCHES NOMINAL
CAPILLARY TUBE LENGTH240.000 INCHES NOMINAL
CONTACT ACTION STIMULUSINCREASE
CONTACT ADJUSTABILITYDEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT RANGE+0.00 TO 60.00 ACTUATION POINT DEGREES FAHRENHEIT
CONTACT ADJUSTMENT TYPEEXTERNAL ACTUATION POINT SCREW
CONTACT LOAD CURRENT RATING1.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
CONTACT LOAD CURRENT RATING2.7 AMPERES RESISTIVE LOAD FIRST VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS550.0 AC AT SEA LEVEL FIRST VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS550.0 DC AT SEA LEVEL SECOND VOLTAGE
FREQUENCY IN HERTZ60.0 SINGLE VOLTAGE
OVERALL HEIGHT5.281 INCHES NOMINAL
OVERALL LENGTH5.000 INCHES NOMINAL
OVERALL WIDTH2.688 INCHES NOMINAL
MOUNTING METHODBRACKET
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
SPECIAL FEATURESMOUNTING DIMENSIONS,THREE 0.281 IN. DIAMETER MOUNTING HOLES,TWO HOLES ON TOP SPACED 2.406 IN. C TO C,ONE HOLE ON BOTTOM 0.547 IN.TO THE LEFT OF VERTICAL CENTERLINE,3.281 IN. VERTICAL DISTANCEBETWEEN MOUNTING CENTERS
TEMP SENSING ELEMENT TYPECAPILLARY TUBE-BULB
TERMINAL TYPETAB W/SCREW