BODY DIAMETER | 0.312 INCHES NOMINAL |
BODY LENGTH | 4.000 INCHES NOMINAL |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET |
CONTACT ADJUSTMENT RANGE | +200.00 TO 1500.00 ACTUATION POINT DEGREES FAHRENHEIT AND +200.00 TO 1500.00 DEACTUATION POINT DEGREES FAHRENHEIT |
CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW |
CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CONTACT LOAD CURRENT RATING | 100.0 MILLIAMPERES RESISTIVE LOAD THIRD VOLTAGE |
CONTACT STIMULUS RATING | 675.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 648.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL SECOND VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL FIRST VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL THIRD VOLTAGE |
FEATURES PROVIDED | TAMPER PROOF CAP |
OVERALL LENGTH | 9.312 INCHES NOMINAL |
MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
MOUNTING METHOD | THREADED BUSHING |
NOMINAL THREAD SIZE | 0.500 INCHES SINGLE THREADED BUSHING |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
OPERATING TEMP RATING | -100.0 FAHRENHEIT MINIMUM AND 750.0 FAHRENHEIT MAXIMUM |
STYLE DESIGNATOR | CYLINDRICAL |
TEMP SENSING ELEMENT TYPE | IMMERSION WELL |
TERMINAL TYPE | WIRE LEAD |
THREAD CLASS | 2A SINGLE THREADED BUSHING |
THREAD LENGTH | 0.375 INCHES NOMINAL SINGLE THREADED BUSHING |
THREAD SERIES DESIGNATOR | UNF SINGLE THREADED BUSHING |
THREAD QUANTITY PER INCH | 20 SINGLE THREADED BUSHING |