5930-00-615-9024 SWITCH,THERMOSTATIC Index 8140-00-615-9028 PIN CLOSURE

National Stock Number:
5930-00-615-9027

Federal Supply Class:
5930

National Item Identification Number:
006159027

Description:
SWITCH,THERMOSTATIC

Detail:
A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).


Manufacturer Information:
161084310001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
173011-1773168KIDDE TECHNOLOGIES, INC
SKSH09268963325VULCAN ELECTRIC CO


Techincal Specification:
BODY LENGTH4.281 INCHES NOMINAL
CONTACT ACTION STIMULUSINCREASE
CONTACT ADJUSTABILITYACTUATION POINT ADJUSTABLE, PRESET
CONTACT ADJUSTMENT RANGE-100.00 TO 400.00 ACTUATION POINT DEGREES FAHRENHEIT
CONTACT ADJUSTMENT TYPEEXTERNAL ACTUATION POINT SHAFT
CONTACT LOAD CURRENT RATING10.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
CONTACT LOAD CURRENT RATING2.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE
CONTACT LOAD CURRENT RATING2.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE
CONTACT LOAD CURRENT RATING5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE
CONTACT STIMULUS RATING170.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT
CONTACT VOLTAGE RATING IN VOLTS115.0 DC AT SEA LEVEL THIRD VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS115.0 AC AT SEA LEVEL SECOND VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS230.0 AC AT SEA LEVEL FIRST VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS28.0 DC AT SEA LEVEL FOURTH VOLTAGE
FREQUENCY IN HERTZ60.0 FIRST VOLTAGE
FREQUENCY IN HERTZ60.0 SECOND VOLTAGE
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS1.125 INCHES NOMINAL
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS0.750 INCHES NOMINAL
OVERALL HEIGHT1.656 INCHES NOMINAL
OVERALL LENGTH4.906 INCHES NOMINAL
OVERALL WIDTH1.062 INCHES NOMINAL
MEDIA FOR WHICH DESIGNEDGAS
MOUNTING FACILITY PATTERNISOSCELES TRIANGLE
MOUNTING METHODBRACKET AND UNTHREADED HOLE
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
OPERATING TEMP RATING-100.0 FAHRENHEIT MINIMUM AND 500.0 FAHRENHEIT MAXIMUM
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS0.750 INCHES NOMINAL
STYLE DESIGNATORRECTANGULAR
TEMP SENSING ELEMENT TYPEINTERNAL SENSOR
TERMINAL TYPEWIRE LEAD
UNTHREADED MOUNTING HOLE DIAMETER0.219 INCHES NOMINAL