| BULB LENGTH | 1.938 INCHES NOMINAL |
| CAPILLARY TUBE LENGTH | 72.000 INCHES NOMINAL |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +270.00 TO 380.00 ACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT LOAD CURRENT RATING | 4.6 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
| CONTACT LOAD CURRENT RATING | 1.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
| CONTACT LOAD CURRENT RATING | 13.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 2.7 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL THIRD VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL SECOND VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL FOURTH VOLTAGE |
| FEATURES PROVIDED | TUBING END SEAL CONNECTION |
| OVERALL HEIGHT | 2.687 INCHES NOMINAL |
| OVERALL LENGTH | 5.000 INCHES NOMINAL |
| OVERALL WIDTH | 5.281 INCHES NOMINAL |
| MOUNTING METHOD | BRACKET(S) |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| SPECIAL FEATURES | PIPE FITTING CONNECTION |
| TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
| TERMINAL TYPE | TAB W/SCREW |