5935-00-752-2755 JACK,TIP Index 6110-00-752-2757 SWITCHING UNIT,POWER TRANSFER

National Stock Number:
5930-00-752-2756

Federal Supply Class:
5930

National Item Identification Number:
007522756

Description:
SWITCH,THERMOSTATIC

Detail:
A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).


Manufacturer Information:
222-10NL222111919278DETROIT SWITCH INC
222111919278DETROIT SWITCH INC


Techincal Specification:
OVERALL LENGTH5.000 INCHES NOMINAL
OVERALL HEIGHT5.594 INCHES NOMINAL
OVERALL WIDTH2.688 INCHES NOMINAL
BODY LENGTH4.782 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED
CONTACT ACTION STIMULUSINCREASE
CONTACT ADJUSTABILITYDEACTUATION POINT NOT ADJUSTABLE AND
ACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT RANGE120.00 TO 210.00 ACTUATION POINT DEGREES FAHRENHEIT
CONTACT ADJUSTMENT TYPEEXTERNAL ACTUATION POINT SCREW
CONTACT VOLTAGE RATING IN VOLTS550.0 AC AT SEA LEVEL FIRST VOLTAGE
550.0 DC AT SEA LEVEL THIRD VOLTAGE
115.0 DC AT SEA LEVEL FOURTH VOLTAGE
FREQUENCY IN HERTZ60.0 SINGLE VOLTAGE
CONTACT LOAD CURRENT RATING2.7 AMPERES RESISTIVE LOAD FIRST VOLTAGE
13.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
1.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE
4.6 AMPERES RESISTIVE LOAD FOURTH VOLTAGE
TEMP SENSING ELEMENT TYPECAPILLARY TUBE-BULB
CAPILLARY TUBE LENGTH120.000 INCHES NOMINAL
BULB LENGTH3.625 INCHES NOMINAL
BULB DIAMETER0.688 INCHES NOMINAL
TERMINAL TYPETAB W/SCREW
MOUNTING METHODBRACKET
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS2.406 INCHES NOMINAL
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS0.656 INCHES NOMINAL
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS3.281 INCHES NOMINAL