STYLE DESIGNATOR | RECTANGULAR |
OVERALL LENGTH | 3.187 INCHES NOMINAL |
OVERALL HEIGHT | 6.938 INCHES NOMINAL |
OVERALL WIDTH | 1.562 INCHES NOMINAL |
BODY HEIGHT | 2.750 INCHES NOMINAL |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND |
| ACTUATION POINT ADJUSTABLE |
CONTACT ADJUSTMENT RANGE | 75.00 TO 95.00 ACTUATION POINT DEGREES FAHRENHEIT AND |
| 75.00 TO 95.00 DEACTUATION POINT DEGREES FAHRENHEIT |
CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT KNOB WITH SCALE AND |
| EXTERNAL ACTUATION POINT KNOB WITH SCALE |
CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL FIRST VOLTAGE |
| 115.0 AC AT SEA LEVEL SECOND VOLTAGE |
CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| 15.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
MEDIA FOR WHICH DESIGNED | GAS |
TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
CAPILLARY TUBE LENGTH | 6.000 INCHES NOMINAL |
BULB LENGTH | 4.188 INCHES NOMINAL |
BULB DIAMETER | 0.750 INCHES NOMINAL |
TERMINAL TYPE | WIRE LEAD |
MOUNTING METHOD | UNTHREADED HOLE |
UNTHREADED MOUNTING HOLE DIAMETER | 0.219 INCHES NOMINAL |
MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.250 INCHES NOMINAL |
FEATURES PROVIDED | TUBING END SEAL CONNECTION |
SPECIAL FEATURES | 0.500 IN. FITTING FOR PIPE FITTING CONNECTION |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF |