DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.930 INCHES MINIMUM AND 0.944 INCHES MAXIMUM |
CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE AND 1.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE AND 1.0 AMPERES LAMP LOAD SECOND VOLTAGE |
CONTACT STIMULUS RATING | 135.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 125.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SECOND VOLTAGE |
FEATURES PROVIDED | HERMETICALLY SEALED CASE |
FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE |
III OVERALL LENGTH | 0.850 INCHES NOMINAL |
III STYLE DESIGNATOR | DISC |
PROPRIETARY CHARACTERISTICS | PACS |
MEDIA FOR WHICH DESIGNED | GAS |
MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
OPERATING TEMP RATING | -85.0 DEG FAHRENHEIT MINIMUM AND 257.0 DEG FAHRENHEIT MAXIMUM |
OVERALL HEIGHT | 0.660 INCHES MINIMUM AND 0.750 INCHES MAXIMUM |
TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
TERMINAL TYPE | WIRE LEAD |
UNTHREADED MOUNTING HOLE DIAMETER | 0.133 INCHES MINIMUM AND 0.147 INCHES MAXIMUM |
BODY DIAMETER | 0.680 INCHES NOMINAL |
CONTACT ACTION STIMULUS | INCREASE |