CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL |
| 28.0 DC AT SEA LEVEL |
CONTACT LOAD CURRENT RATING | 250.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL |
| 500.0 MILLIAMPERES RESISTIVE LOAD AND |
| 50.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL |
TERMINAL TYPE | TAB, SOLDER LUG |
SWITCH ACTUATOR INDEXING POSITION QUANTITY | 24 SINGLE ACTUATOR |
STYLE DESIGNATOR | CIRCULAR WAFER, BUSHING MOUNT |
OVERALL LENGTH | 6.189 INCHES NOMINAL |
OVERALL HEIGHT | 2.500 INCHES NOMINAL |
OVERALL WIDTH | 2.062 INCHES MAXIMUM |
INDIVIDUAL SECTION QUANTITY | 8 |
SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
POLE QUANTITY | 1 EACH SECTION REAR |
THROW QUANTITY | 23 EACH SECTION REAR |
CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES EACH SECTION REAR |
SWITCH ACTUATOR POSITIONING INCREMENT | 15.0 DEGREES SINGLE ACTUATOR |
SWITCH ACTUATOR STOP DEVICE TYPE | FIXED STOP SINGLE ACTUATOR |
SHAFT TYPE | ROUND, FLATTED SINGLE ACTUATOR |
FIRST FLAT LENGTH | 0.440 INCHES NOMINAL SINGLE ACTUATOR |
FLAT HEIGHT | 0.216 INCHES NOMINAL SINGLE ACTUATOR |
SHAFT DIAMETER | 0.250 INCHES NOMINAL SINGLE ACTUATOR |
SHAFT LENGTH | 0.562 INCHES NOMINAL SINGLE ACTUATOR |
NONTURN DEVICE TYPE | FLATTED BUSHING AT 9:00 O'CLOCK |
MOUNTING METHOD | BRACKET AND |
| UNTHREADED HOLE 2ND MOUNTING FACILITY |
UNTHREADED MOUNTING HOLE DIAMETER | 0.160 INCHES NOMINAL 2ND MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNS 1ST MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.375 INCHES 1ST MOUNTING FACILITY |
THREAD CLASS | 2A 1ST MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 32 1ST MOUNTING FACILITY |
THREAD LENGTH | 0.312 INCHES MINIMUM 1ST MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE 2ND MOUNTING FACILITY |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.500 INCHES NOMINAL 2ND MOUNTING FACILITY |
SHAFT FLAT/SLOT ANGULAR LOCATION | 285.0 DEGREES FROM NONTURN DEVICE SINGLE ACTUATOR |
OPERATING TEMP RANGE | -65.0 TO 85.0 DEG CELSIUS |
DETENT ROTATIONAL TORQUE RANGE | 2.000 TO 6.000 INCH-POUNDS SINGLE ACTUATOR |