5930-01-052-7354 SWITCH ASSEMBLY Index 5930-01-052-7356 SWITCH,ROTARY

National Stock Number:
5930-01-052-7355

Federal Supply Class:
5930

National Item Identification Number:
010527355

Description:
SWITCH,STEPPING

Detail:
AN ELECTROMAGNETICALLY ACTUATED SWITCH HAVING CONTACT WIPERS WHICH ARE SUCCESSIVELY ROTATED OVER FIXED BANK CONTACTS. THE CONTACT WIPERS ARE PROGRESSIVELY ADVANCED OVER THE FIXED BANK CONTACTS THROUGH A REPETITIVE SERIES OF STEPPING OPERATIONS. THE STEPPING OPERATION MAY BE A CONTINUOUS FORWARD ROTATION ACTING THROUGH 360 DEGREES TO RETURN TO ITS NORMAL UNOPERATED POSITION OR IT MAY BE DESIGNED TO INCLUDE AN ELECTROMAGNETIC AND/OR MECHANICAL MEANS FOR RELEASING AND RESETTING THE SWITCH TO ITS RELEASED POSITION FOR A SUBSEQUENT OPERATION. THE CONTACT WIPERS MAY BE MECHANICALLY HELD IN CONTACT WITH THE FIXED BANK CONTACTS AFTER THE ARMATURE OF THE ACTUATING COIL HAS RELEASED. THE SWITCH MAY BE RELEASED AT THE END OF ITS TRAVEL OR AT ANY INTERMEDIATE POSITION. IT INCLUDES ITEMS DESIGNED WITH TWO ELECTROMAGNETIC ACTUATORS THAT ENABLE THE SWITCH TO OPERATE IN EITHER DIRECTION. FOR ITEMS HAVING THE DUAL FUNCTION OF A SWITCH AND A RELAY ASSEMBLED TOGETHER ON A COMMON MOUNTING, SEE RELAY-SWITCH. FOR OTHER THAN ELECTROMAGNETICALLY ACTUATED SWITCHES WHOSE CONTACT WIPERS ARE MANUALLY ROTATED OVER FIXED BANK CONTACTS, SEE SWITCH, ROTARY. EXCLUDES RELAY, ROTARY AND SWITCH, TELEPHONE (AS MODIFIED).


Manufacturer Information:
182235-00181840SAIA-BURGESS INC.


Techincal Specification:
DRIVE TYPEDIRECT
BANK LEVEL QUANTITY4
AUXILIARY OFF-NORMAL CONTACT ARRANGEMENT4E
AUXILIARY INTERRUPTER CONTACT ARRANGEMENT4D
COIL TYPEDRIVE
CONTACT QUANTITY PER BANK LEVEL18
CONTROL METHODREMOTE
CURRENT TYPEDC
MAGNETIC COIL QUANTITY4
OVERALL HEIGHT3.312 INCHES NOMINAL
OVERALL LENGTH7.125 INCHES NOMINAL
OVERALL WIDTH3.984 INCHES MAXIMUM
MOUNTING CONFIGURATIONFOUR NO. 10(0.190 IN.)-32 THD SCREWS ON 2.812 IN. BY 6.625 IN. MTG CENTERS
MOUNTING METHODBRACKET
OPERATING CURRENT RATING3.6 AMPERES MINIMUM AND 7.7 AMPERES MAXIMUM
STEPPING DIRECTIONBIDIRECTIONAL
VOLTAGE RATING22.0 VOLTS MINIMUM AND 30.0 VOLTS MAXIMUM
WIPER CONTACT QUANTITY PER BANK LEVEL3