CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL |
| 28.0 DC AT SEA LEVEL |
CONTACT LOAD CURRENT RATING | 100.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL |
| 200.0 MILLIAMPERES RESISTIVE LOAD AND |
| 20.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL |
TERMINAL TYPE | CLIP |
SWITCH ACTUATOR INDEXING POSITION QUANTITY | 2 1ST ACTUATOR |
| 4 2ND ACTUATOR |
STYLE DESIGNATOR | CIRCULAR WAFER, BUSHING MOUNT |
OVERALL LENGTH | 3.965 INCHES NOMINAL |
OVERALL DIAMETER | 1.344 INCHES MAXIMUM |
INDIVIDUAL SECTION QUANTITY | 4 |
SWITCH CONTACT BASIC DESIGN | NONPILE-UP NONSYMMETRICAL |
SWITCH ACTUATOR POSITIONING INCREMENT | 90.0 DEGREES 1ST ACTUATOR |
| 30.0 DEGREES 2ND ACTUATOR |
SHAFT TYPE | ROUND, FLATTED ALL ACTUATORS |
FIRST FLAT LENGTH | 0.250 INCHES NOMINAL 1ST ACTUATOR |
| 0.250 INCHES NOMINAL 2ND ACTUATOR |
FLAT HEIGHT | 0.216 INCHES NOMINAL 1ST ACTUATOR |
| 0.093 INCHES NOMINAL 2ND ACTUATOR |
SHAFT DIAMETER | 0.250 INCHES NOMINAL 1ST ACTUATOR |
| 0.125 INCHES NOMINAL 2ND ACTUATOR |
SHAFT LENGTH | 0.562 INCHES NOMINAL 1ST ACTUATOR |
| 0.500 INCHES NOMINAL 2ND ACTUATOR |
NONTURN DEVICE TYPE | TAB AT 3:00 O'CLOCK |
NONTURN DEVICE RADIUS | 0.375 INCHES NOMINAL AT 3:00 O'CLOCK |
MOUNTING METHOD | THREADED BUSHING SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNEF SINGLE MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.375 INCHES SINGLE MOUNTING FACILITY |
THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
THREAD LENGTH | 0.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF |
SHAFT FLAT/SLOT ANGULAR LOCATION | 270.0 DEGREES FROM NONTURN DEVICE ALL ACTUATORS |
OPERATING TEMP RANGE | -65.0 TO 85.0 DEG CELSIUS |
DETENT ROTATIONAL TORQUE RANGE | 0.800 TO 4.000 INCH-POUNDS ALL ACTUATORS |
PRECIOUS MATERIAL | SILVER |
PRECIOUS MATERIAL AND LOCATION | TERMINALS AND ROTOR BLADES SILVER |